FENG Zhong-ju, CHEN Hui-yun, YUAN Feng-bin, YIN Hong-hua, LI Xiao-xiong, LIU Chuang, ZHANG Fu-qiang, WANG Meng-meng, LI Shao-jie. Vertical bearing characteristics of bridge pile foundation under pile-soil-fault coupling action[J]. Journal of Traffic and Transportation Engineering, 2019, 19(2): 36-48. doi: 10.19818/j.cnki.1671-1637.2019.02.004
Citation: FENG Zhong-ju, CHEN Hui-yun, YUAN Feng-bin, YIN Hong-hua, LI Xiao-xiong, LIU Chuang, ZHANG Fu-qiang, WANG Meng-meng, LI Shao-jie. Vertical bearing characteristics of bridge pile foundation under pile-soil-fault coupling action[J]. Journal of Traffic and Transportation Engineering, 2019, 19(2): 36-48. doi: 10.19818/j.cnki.1671-1637.2019.02.004

Vertical bearing characteristics of bridge pile foundation under pile-soil-fault coupling action

doi: 10.19818/j.cnki.1671-1637.2019.02.004
More Information
  • Author Bio:

    FENG Zhong-ju (1965-), male, professor, PhD, ysf@gl.chd.edu.cn

    CHEN Hui-yun (1995-), female, doctoral student, 992387012@qq.com

  • Received Date: 2018-10-11
  • Publish Date: 2019-04-25
  • Based on the Hainan Puqian Bridge, the distance effect and bearing characteristics of bridge pile foundation under the fault-pile-rock interaction were analyzed by the indoor model test and numerical simulation. Research result shows that, in the model test, for a pile foundation with a diameter of 6.3 cm and a length of 60 cm, when the horizontal distance between the fault and the pile foundation increases from 9.45 cm to 22.05 cm, the bearing capacity of pile foundation increases by 26.7%. When the horizontal distance increases from 22.05 cm to 31.50 cm, the bearing capacity increases by only 3.8%, and the influence degree of the horizontal distance on the vertical bearing capacity reduces to 6.5% and may be neglected. When the length of pile foundation is constant and the load is the same, the smaller the horizontal distance, the smaller the change of axial force of pile foundation. The horizontal distance increases from 9.45 cm to 22.05 cm, the side resistance of pile foundation increases by 0.059 kN at the 30 cm of pile foundation length, and the influence degree decreases by 44.5%. When the horizontal distance increases from 22.05 cm to 31.50 cm, the side resistance increases by 0.029 kN, and the influence degree decreases by 8.3%. In the numerical simulation, under the condition that the diameter, length and overburden thickness of pile foundation are 1.5, 30, and 10 m, respectively, when the horizontal distance increases from 1.5 m to 6.0 m, the increment of the bearing capacity reduces from 11.0% to 6.5%. When the horizontal distance increases from 6.0 m to 7.5 m, the increment reduces to 4.9%. When the horizontal distance reduces from 7.5 m to 1.5 m, the axial force of pile foundation decreases gradually along the length direction of pile foundation. When the length of pile foundation is constant and the load is the same, the smaller the horizontal distance, the smaller the change of axial force of pile foundation. When the horizontal distance increases from 1.5 m to 6.0 m, the side resistance of pile foundation at the 16 m of pile foundation length increases by 1.90 MN, and the influence degree of the horizontal distance on the side resistance reduces by 28.0%. When the horizontal distance increases from 6.0 m to 7.5 m, the pile side resistance increases by 0.33 MN, and the influence degree decreases by 5.0%. The results of model test and numerical simulation show that the vertical bearing characteristics of bridge pile foundation are greatly affected by the horizontal distance between the fault and the pile foundation when the horizontal distance is less than five times the pile foundation diameter. When the horizontal distance is more than five times the pile foundation diameter, its influence is smaller or even negligible. The side resistance ratio and influence degrees of the horizontal distance on the bearing capacity and side resistance of pile foundation decrease rapider in the numerical simulation than in the indoor model test. When the horizontal distance is five times the pile foundation diameter, the numerical simulation values reduce by 0.174, 2.2%, and 6.0% compared with the indoor model test values, respectively. Therefore, the numerical simulation result is ideal and can be used as engineering reference.

     

  • loading
  • [1]
    LIU Chuang, FENG Zhong-ju, ZHANG Fu-qiang, et al. Dynamic response of rock-sockted pile foundation for extra-large bridge under earthquake action[J]. Journal of Traffic and Transportation Engineering, 2018, 18 (4): 53-62. (in Chinese). doi: 10.3969/j.issn.1671-1637.2018.04.006
    [2]
    LIN Jin-shun. Construction technology of large-diameter pile foundation in fault fracture zone of Shaxi Extra Large Bridge[J]. Highway, 2019 (3): 106-110. (in Chinese). doi: 10.3969/j.issn.1671-2668.2019.03.025
    [3]
    GOEL R K, CHOPRA A K. Nonlinear analysis of ordinary bridges crossing fault-rupture zones[J]. Journal of Bridge Engineering, 2009, 14 (3): 216-224. doi: 10.1061/(ASCE)1084-0702(2009)14:3(216)
    [4]
    DI LAORA R, ROVITHIS E. Kinematic bending of fixed-head piles in nonhomogeneous soil[J]. Journal of Geotechnical and Geoenvironmental Engineering, 2015, 141 (4): 04014126-1-10. doi: 10.1061/(ASCE)GT.1943-5606.0001270
    [5]
    SAIIDI M, VOSOOGHI A, CHOI H, et al. Shake table studies and analysis of a two-span RC bridge model subjected to a fault rupture[J]. Journal of Bridge Engineering, 2014, 19 (8): A4014003-1-9. doi: 10.1061/(ASCE)BE.1943-5592.0000478
    [6]
    JIN Bao-he. Design of bridges located in poor geologic zone of pinnate fault[J]. Bridge Construction, 1996 (4): 24-26. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-QLJS604.006.htm
    [7]
    XIA Chun-xu, LIU Ying-zhou, LIU Chun-guang. Characteristic response analysis of bridge piers under multi-pulse near-fault earthquake excitation[J]. Journal of Vibration and Shock, 2017, 36 (2): 95-100, 110. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-ZDCJ201702015.htm
    [8]
    SHUAI Shao-jun, DAI Wan-jiang, LUO Si-bi. Study on the design of bridges across fault zones[J]. Highway, 2016 (4): 127-130. (in Chinese). doi: 10.3969/j.issn.1002-0268.2016.04.020
    [9]
    DAI Zi-hang, CHEN Lin-jing. Two numerical solutions of laterally loaded piles installed in multi-layered soils by m method[J]. Chinese Journal of Geotechnical Engineering, 2007, 29 (5): 690-696. (in Chinese). doi: 10.3321/j.issn:1000-4548.2007.05.010
    [10]
    WANG Nian-xiang, ZHANG Wei-min. Centrifuge modeling on bearing behavior of large bridge group pile foundation[J]. Journal of Highway and Transportation Research and Development, 2008, 25 (4): 79-83. (in Chinese). doi: 10.3969/j.issn.1002-0268.2008.04.016
    [11]
    ZHAO Ming-hua, LUO Wei-hua, LEI Yong, et al. In-site load-carrying characteristics test of rock-socked piles of Mishui River Bridge[J]. Journal of Hunan University (Natural Sciences), 2014, 41 (3): 1-6. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-HNDX201403001.htm
    [12]
    ZENG Bo. Construction of large diameter and deep pile foundation in fault fracture zone[J]. Journal of China and Foreign Highway, 2002, 22 (5): 80-81. (in Chinese). doi: 10.3969/j.issn.1671-2579.2002.05.027
    [13]
    FENG Zhong-ju, WANG Fu-chun, SU Hang-zhou, et al. Centrifuge model test on effect of underground loess cave on vertical bearing characteristic of bridge pile foundation[J]. Journal of Chang'an University (Natural Science Edition), 2017, 37 (2): 35-44. (in Chinese). doi: 10.3969/j.issn.1671-8879.2017.02.005
    [14]
    FENG Zhong-ju, WANG Fu-chun, ZHANG Qi-lang, et al. Centrifuge model tests of horizontal bearing characteristics of steel pipe concrete composite pile[J]. China Civil Engineering Journal, 2018, 51 (1): 114-123, 128. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-TMGC201801014.htm
    [15]
    CAO Shu-gang, LUO Feng, CHENG Chong-sheng, et al. Surrounding rock control of shaft in water enriched fault fracture zone[J]. Chinese Journal of Rock Mechanics and Engineering, 2014, 33 (8): 1536-1545. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-YSLX201408004.htm
    [16]
    GUO Wei-guo. Treatment of deep pile foundation in fault fracture zone[J]. Highway, 1998 (8): 6-12. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-GLGL199808001.htm
    [17]
    SU Hang-zhou. The study of centrifugal modeling test on load-bearing characteristics affected by loess hidden caves of highway bridges pile foundation[D]. Xi'an: Chang'an University, 2016. (in Chinese).
    [18]
    LAO Wei-kang, ZHOU Li-yun, WANG Zhao. Field test and theoretical analysis on flexible large-diameter rock-socketed steel pipe piles under lateral load[J]. Chinese Journal of Rock Mechanics and Engineering, 2004, 23 (10): 1770-1777. (in Chinese). doi: 10.3321/j.issn:1000-6915.2004.10.033
    [19]
    LI Jin, FENG Zhong-ju, XIE Yong-li. Numerical simulation of large diameter hollow pile bearing performance[J]. Journal of Chang'an University (Natural Science Edition), 2004, 24 (4): 36-39. (in Chinese). doi: 10.3321/j.issn:1671-8879.2004.04.009
    [20]
    LI Yong, YAN Wei-ming, LIU Jing-bo, et al. Study and development on shake table tests of scaled models of bridge engineering[J]. Earthquake Resistant Engineering and Retrofitting, 2013, 35 (5): 1-10. (in Chinese). doi: 10.3969/j.issn.1002-8412.2013.05.001
    [21]
    SHI Wen-qing, WANG Jian-hua, CHEN Jin-jian. Numerical analysis of the laterally loaded pile considering the unlinear characteristic of pile soil interface[J]. Journal of Shanghai Jiaotong University, 2006, 40 (8): 1457-1460. (in Chinese). doi: 10.3321/j.issn:1006-2467.2006.08.043
    [22]
    YUAN Lin-juan, LIU Xiao-sheng, WANG Xiao-gang, et al. Analytic solution of dynamic characteristics and responses of soil-box model for shaking table tests[J]. Chinese Journal of Geotechnical Engineering, 2012, 34 (6): 1038-1042. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-YTGC201206013.htm
    [23]
    DONG Yun-xiu, FENG Zhong-ju, HAO Yu-meng, et al. Experiment on bearing capacity of bridge pile foundations in karst area sand reasonable rock-socketed depth[J]. Journal of Traffic and Transportation Engineering, 2018, 18 (6): 27-36. (in Chinese). doi: 10.3969/j.issn.1671-1637.2018.06.004
    [24]
    LIU Kai-de, LIU Quan-sheng, LIU Bin, et al. Research on control measures and effects for roadway stability in geological anomaly zone[J]. Chinese Journal of Rock Mechanics and Engineering, 2011, 30 (12): 2486-2497. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-YSLX201112014.htm
    [25]
    CHEN Si-xiao, FENG Zhong-ju, HE Jing-bin. Experimental study on engineering characteristics of seawater mortar for bored piles in marine environment[J]. Bridge Construction, 2018, 48 (6): 70-74. (in Chinese). doi: 10.3969/j.issn.1003-4722.2018.06.013
    [26]
    HU Sheng, YANG Hua-zhen, LUO Si-bi, et al. Overall design of Puqian Bridge in Hainan[J]. Bridge Construction, 2016, 46 (1): 94-99. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-QLJS201601022.htm
    [27]
    GAO Guang-yun, SONG Jian. Predictive models for permanent displacement of slopes induced by near-fault pulse-like ground motions[J]. Rock and Soil Mechanics, 2014, 35 (5): 1340-1347. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-YTLX201405020.htm
    [28]
    HUI Ying-xin, MAO Ming-jie, LIU Hai-feng, et al. Influence of structural seismic response of bridges crossing active fault[J]. Journal of Jilin University (Engineering and Technology Edition), 2018, 48 (6): 1725-1734. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-JLGY201806012.htm

Catalog

    Article Metrics

    Article views (1610) PDF downloads(407) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return