| Citation: | ZHANG Feng, LIU Jia-qi, GAO Lei, LIU Guan-zhi. Test method of clip bite force[J]. Journal of Traffic and Transportation Engineering, 2019, 19(3): 27-35. doi: 10.19818/j.cnki.1671-1637.2019.03.004 |
| [1] |
BAŽANT Z P, YU Q, LI G H. Excessive long-time deflections of prestressed box girders. Ⅰ: record-span bridge in Palau and other paradigms[J]. Journal of Structural Engineering, 2012, 138 (6): 676-686. doi: 10.1061/(ASCE)ST.1943-541X.0000487
|
| [2] |
ROBERTSON I N. Prediction of vertical deflections for a long-span prestressed concrete bridge structure[J]. Engineering Structures, 2005, 27 (12): 1820-1827. doi: 10.1016/j.engstruct.2005.05.013
|
| [3] |
TAKÁCS P F. Deformations in concrete cantilever bridges: observations and theoretical modeling[D]. Trondheim: The Norwegian University of Science and Technology, 2002.
|
| [4] |
FU Dan. Working stress tests of prestressed tendons in ground anchorage[D]. Beijing: Tsinghua University, 2010. (in Chinese).
|
| [5] |
FU Dan, GUO Hong-xian, CHENG Xiao-hui, et al. Working stress measurement of prestressed anchor cables: detection mechanism and experimental study of lift-off test[J]. Rock and Soil Mechanics, 2012, 33 (8): 2247-2252. (in Chinese). doi: 10.3969/j.issn.1000-7598.2012.08.002
|
| [6] |
ZHAN Gui-chao, LIU Guan-zhi. Test and analysis on prestressed steel strand tension test based on lift-off method[J]. Highways and Automotive Applications, 2016 (3): 191-193. (in Chinese). doi: 10.3969/j.issn.1671-2668.2016.03.051
|
| [7] |
ZHAO Yu, HONG Lu-jia, ZHOU Yong-jun. Bearing capacity assessment method for PC box girder by testing stress of tendon[J] Journal of Chang'an University (Natural Science Edition), 2019, 39 (1): 61-69. (in Chinese). doi: 10.3969/j.issn.1671-8879.2019.01.009
|
| [8] |
LI Rui-ge. Prestress loss of full prestressed concrete beams by dynamic technology[D]. Wuhan: Huazhong University of Science and Technology, 2015. (in Chinese).
|
| [9] |
AI Hui-lin, CHEN Chao-wei, DAI Wen-da. Study of rapid inspection method for under-anchorage effective prestress in prestressed beams[J]. World Bridges, 2015, 43 (4): 42-46. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-GWQL201504011.htm
|
| [10] |
YU Guo-qiang. The application of prestressed concrete bridge effective prestressed testing technology[J]. Xi'an: Chang'an University, 2013. (in Chinese).
|
| [11] |
YANG Guo-li, LI Rui-ge. Development and prospect of prestress loss detection in prestressed concrete beams[J]. Sichuan Building Science, 2008, 34 (4): 113-116. (in Chinese). doi: 10.3969/j.issn.1008-1933.2008.04.029
|
| [12] |
GUO Qi. Theory and method of effective prestress prediction of beam prestressed composite prestressed system[D]. Xi'an: Chang'an University, 2008. (in Chinese).
|
| [13] |
XU Jiang, WU Xin-jun, SUN Peng-fei. Detecting broken-wire flaws at multiple locations in the same wire of prestressing strands using guided waves[J]. Ultrasonics, 2013, 53 (1): 150-156. doi: 10.1016/j.ultras.2012.05.003
|
| [14] |
CHEN R H L, WISSAWAPAISAL K. An ultrasonic method for measuring tensile forces in a seven-wire prestressing strand[J]. AIP Conference Proceedings, 2002, 615 (1): 1295-1302.
|
| [15] |
ZHANG Ben-niu, YUAN Can, CHEN Zhuo-min, et al. Stress measurement of steel strands based on LC oscillation[J]. Journal of Chongqing Jiaotong University (Natural Science), 2017, 36 (3): 8-12. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-CQJT201703002.htm
|
| [16] |
JIA Qiao-yan. Study on the extant pre-stressed force of the concrete structure in service based on the stress release method[D]. Wuhan: Wuhan University of Technology, 2008. (in Chinese).
|
| [17] |
OU Jin-ping, ZHOU Zhi, WANG Bo. Smart FRP-OFBG bars and their application in reinforced concrete beams[J]. Chinese High Technology Letters, 2005, 15 (4): 23-28. (in Chinese). doi: 10.3321/j.issn:1002-0470.2005.04.006
|
| [18] |
ZHOU Zhi, WU Zhan-jun, ZHAO Xue-feng, et al. Smart monitoring technique of concrete structures based on optical fiber Bragg grating sensors[J]. Journal of Functional Materials, 2003, 34 (3): 344-348. (in Chinese). doi: 10.3321/j.issn:1001-9731.2003.03.039
|
| [19] |
HE Shuan-hai, ZHAO Xiang-mo, MA Jian, et al. Review of highway bridge inspection and condition assessment[J]. China Journal of Highway and Transport, 2017, 30 (11): 63-80. (in Chinese). doi: 10.3969/j.issn.1001-7372.2017.11.007
|
| [20] |
ZHONG Zheng-qiang, DAI Dian, YUAN Jian-wei. Development and application of prestress testing system based on Hooke theorem[J]. Journal of Central South University (Science and Technology), 2018, 49 (3): 725-731. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-ZNGD201803028.htm
|
| [21] |
DONG Yan, LIU Jia-qi, ZHANG Feng. Instrument development and engineering application of effective prestressing test under anchor[J]. Journal of China and Foreign Highway, 2017, 37 (5): 117-120. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-GWGL201705025.htm
|
| [22] |
LUO Bin, TANG Shu-ming, CHENG Xiao-hui, et al. Techniques of reverse drawing detection for prestress under anchor[J]. Technology of Highway and Transport, 2012 (1): 12-14, 22. (in Chinese). doi: 10.3969/j.issn.1009-6477.2012.01.004
|
| [23] |
XIA Jing, YUAN Jian-wei. Research on detection method of effective prestress under anchor by lift-off method[J]. Highways and Automotive Applications, 2016 (6): 210-212. (in Chinese). doi: 10.3969/j.issn.1671-2668.2016.06.056
|
| [24] |
CHENG Jian-bo, YAO Chen, ZHANG Feng. Experimental study of lift-off method for detecting service stress of prestressed strand[J]. Highways and Automotive Applications, 2015 (3): 181-184. (in Chinese). doi: 10.3969/j.issn.1671-2668.2015.03.052
|
| [25] |
REN Chuan-ting, LIU Wei-chao, LING Tian-qing, et al. Primary investigation for unevenness of effective prestress[J]. Technology of Highway and Transport, 2015 (6): 63-67, 72. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-GLJT201506015.htm
|
| [26] |
WU Yu-cai, ZHANG Guo-bing, LI Fen. Prestressing steel wire drawing force testing technology[J]. Transportation Science and Technology, 2006 (5): 36-37, 59. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-SKQB200605014.htm
|
| [27] |
HAN Kan, LI Deng-ke, WU Guan-zhong. Pull-out tests on anchoring force of prestressed anchor cables[J]. Chinese Journal of Geotechnical Engineering, 2011, 33 (S1): 385-387. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-YTGC2011S1074.htm
|
| [28] |
ZHANG Feng, GAO Lei, XU Xiang-feng, et al. Testing technology of under-anchorage effective prestress of steel strand in construction period[J]. Journal of Northeastern University (Natural Science), 2017, 38 (8): 1201-1205. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-DBDX201708028.htm
|
| [29] |
ZHAGN Feng, GAO Lei, HAN Fu-zhou. Experiment on bite force of prestressed steel wire clip-type anchors[J]. Journal of Basic Science and Engineering, 2017, 25 (6): 1273-1281. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-YJGX201706018.htm
|
| [30] |
KONG Qing-hua, WANG Si-ling, XIE Qiang. Structure analysis of wedge type single hole prestressed anchor[J]. Grinder and Grinding, 2005 (3): 10-11. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-SCYM200503005.htm
|
| [31] |
FENG Tian-peng, WANG Dong, HAN Fu-zhou, et al. New testing technology for friction coefficient of prestressed duct[J]. Construction Technology, 2017, 46 (9): 39-42. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-SGJS201709012.htm
|
| [32] |
SHI Nan-xiang. Inspection and monitoring of prestressed anchoring system[J]. Journal of Chongqing Jianzhu University, 2002, 24 (2): 43-46. (in Chinese). https://www.cnki.com.cn/Article/CJFDTOTAL-JIAN200202010.htm
|