FAN Hou-bin, FAN Zhi-hua, DONG Ming-gang. Mechanism of pollutant movement in a long highway tunnel and one-dimensional analysis[J]. Journal of Traffic and Transportation Engineering, 2002, 2(3): 57-59.
Citation: FAN Hou-bin, FAN Zhi-hua, DONG Ming-gang. Mechanism of pollutant movement in a long highway tunnel and one-dimensional analysis[J]. Journal of Traffic and Transportation Engineering, 2002, 2(3): 57-59.

Mechanism of pollutant movement in a long highway tunnel and one-dimensional analysis

More Information
  • Author Bio:

    FAN Hou-bin(1973-), male, a doctoral student of Tongji University, engaged in research of tunnel engineering

  • Received Date: 2001-12-28
  • Publish Date: 2002-09-25
  • The ventilation of a long highway tunnel is one of the concerns of highway builders.This ventilation process is also the movement of the pollutants in the wind.The latter mainly includes the forms of molecular diffusion, convective movement, turbulent current diffusion and attenuating transformation.By the law of conservation of quality, the diffusion equations of pollutant movement and pollutant turbulence can be followed.These diffusion equations, wind flow equation, boundary conditions and primary conditions contribute to the convection of the mixture of pollutants and air, the equation of diffusive mathematics mechanics.Finally, the one dimensional theory under the regularly given conditions is analyzed and the practical example is calculated, the results show that the simulating calculation of the pollutant movement in the wind in a long highway tunnel only needs the consideration of convection movement and turbulent current diffusion.

     

  • loading
  • [1]
    Axel Bring, Tor-Goran Malmstrom, Carl Alex Boman. Simulation and measurement of road tunnel ventilation [J]. Tunnelling and Underground Space Technology, 1997, 12(3): 417-424.
    [2]
    章梓雄, 董曾南. 粘性流体力学[M]. 北京: 清华大学出版社, 1999.
    [3]
    余常昭. 环境流体力学导论[M]. 北京: 清华大学出版社, 1998.
    [4]
    Wu Y, Bakar M Z A. Control of smokein tunnel fires using longitudinal ventilation systems——a study of the critical velocity[J]. Fire Safety Journal, 2000, 35 (4): 363-390.
    [5]
    Shroff Gajendra H, Wan Ping K. Tunnel ventilation building emissions control options[A]. Proceeding of the Air & Waste Management Association's Annual Meeting & Exhibition 1998[C]. Air & Waste Management Assoc, Pittsburrgh, PA, USA, 14pp 98-RP93B. 02.